Acetaldehyde Generation
| Sample Type | Required Quantity | Equipment Used |
| Resin Flake Preform Bottle |
350 grams | Rheometer Gas Chromatograph |
Purpose
This procedure determines the AA generated by a resin as a function of time at a given temperature.
Description
Resin is dried to <50 ppm moisture in a vacuum oven at 165°C and loaded into a capillary rheometer that has been equilibrated to a specified temperature. The capillary rheometer temperature is typically 285°C for this test but can be set anywhere between 260°C-290°C in order to match the temperatures that the resin would encounter during injection molding. The resin samples are extruded from the rheometer into cold water after holding for timed intervals of 4 minutes, 6 minutes, 8 minutes, 10 minutes and 12 minutes, (typically a sample of the resin at 0 dwell time is run also in order to determine a dried resin content value). The extrudate is quickly towel and air dried and is then cryogenically ground to a small particle size and analyzed for AA content as described in the AA Content description. The AA generation rate is shown graphically as a function of dwell time.
Video Demonstration
← Go back to Plastic Materials Testing

PTI delivers innovation, development and comprehensive technical services to progressive companies engaged in plastic packaging.

Contact
Phone: +41 24 423 9530
Fax: +41 24 423 9531
E-Mail