Water Bottles

Haze and Color Measurement (Preform & Container)

 

Sample Type Required Quantity Equipment Used
Preforms
Bottles
6
Minolta Spectrophotometer

 

Purpose
This procedure is used to determine the amount of haze and the degree of color exhibited by a preform or container sidewall. This is an indication of how effectively the material was processed and/or the material’s ability to be processed.

Description
The samples are measured in terms of L*, a*, b*, DE* and Haze: L* (100=white; 0=black), a* (positive=red; negative=green; 0=gray), b* (positive=yellow; negative=blue; 0=gray), DE is a mathematical equation which takes into account the values of L*, a* and b*. Haze measures the scattering of light through the sample; the higher the number the more haze. The haze can be used as an indicator of the presence of crystallinity in the sample.

 

Video Demonstration


 

← Go back to Plastic Materials Testing

Our Mission


PTI delivers innovation, development and comprehensive technical services to progressive companies engaged in plastic packaging.


 

Contact

Phone: +41 24 423 9530
Fax: +41 24 423 9531
E-Mail