Extraction: Hot-Filled Container
| Sample Type | Required Quantity | Equipment Used |
| Bottles | 10 |
PTI LMS - Laser Measurement System |
Purpose
This procedure evaluates the performance of a heat set bottle when
filled with heated water. The methodology used simulates filling and
capping as found in production.
Description
The physical measuring consists of the following: initial bottle
diameters measured at designated heights 90° from the parting lines,
overall bottle heights and overfill volumes. After the initial
measurements are taken, the bottles are filled to the brim with heated
water. A head space is created after allowing the bottles to set for a
pre-determined amount of time and the bottles are capped and sealed. The
bottles are allowed to set for a pre-determined amount of time and are
then immersed into cool water and remain there until the bottles are
room temperature to touch. The bottles are then removed and dried. Final
maximum and minimum diameter measurements are then taken at the same
heights as the initial measurements. Overfill volumes are repeated and
the overall heights are taken with the closure removed. The bottles are
cut at designated heights and then weighed.